Csi safe is showing punching value as n/c
WebJun 11, 2009 · Yes, that's what I decided in the end. I still hope CSI will actually update SAFE v12 and fix some bugs. I found that, as you thought, the punching area isn't …
Csi safe is showing punching value as n/c
Did you know?
WebJan 16, 2024 · SAFE Punching shear design overwrites- Location type. thread803-462531. S_P (Structural) (OP) 16 Jan 20 21:06. Hi I'm trying to overwrite the location type of an interior column to be of "Corner" location type. I created a new model from an initial "Flat Slab" template with default settings but without drops, overwrote the location type of one ... WebJan 13, 2003 · For example if you have an 80 cm mat you ought to give a clearance of 40 cms at least from the face of the load size specified in the software. If you specified a 30 cms size load you need to provide a clearance of 55 cms at least. CSI have an article "SAFE Technical Note 1" entitled "How SAFE Calculates Punching Shear For the ACI 318-95 …
WebNote: after analysis and design if N/C is showing it means then is no problem of punching shear there. This will be shown when strap beam is provided from footing to footing. 10. Footing Design (Reinforcement Details): After analysis. Go to run analysis and Design. Go to Display > Show Slab Design > design basis > finite element method. Webottegroup.com
WebSAFE Punching Shear - Free download as PDF File (.pdf), Text File (.txt) or read online for free. ... CONCLUSION The SAFE results show an exact comparison with the independent results. ... Point C has the largest absolute value of v u , thus v max = 1.792 N/mm2. EXAMPLE IS 456-00 RC-PN-001 - 5 WebJun 20, 2024 · In your case for IS 456-2000 code, the shear reinforcement value should be in 'mm2/m' units. You may verify this manually, using critical shear force values of relevant members (beam or columns) output by ETABS.
WebJun 20, 2024 · 3-Even when you export same slab in SAFE the punching shear results vary in both models .There is significant difference in unbalanced moment value in both …
WebFeb 17, 2024 · "Punching shear results are displayed as a ratio of maximum calculated shear with respect to capacity. A ratio above 1.0 would indicate capacity was exceeded somewhere along the critical section. The ratio is displayed for each column (and restrained point) and each point load. A notation of N/C means the value was not calculated by the … popular hr metricsWebMay 12, 2024 · 26. 25 BY: ASAYE CHEMEDA (E-mail: [email protected]) AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016 Figure 23 Then, check on ‘Labels’, ‘Show Width’ and ‘Show Stations’ in the ‘Design Strip Objects’ box and press ‘OK’ and the following window appears displaying the design strips in the two directions. … popular house siding colorsAnswer: SAFEchecks punching shear twice, once for column punching through the drop panel, then once for drop-panel punching through the slab. In this sequence, SAFE traces the punching perimeters required for calculation. An assumption fundamental to the punching-shear check is that each column has … See more Answer:A few thing to keep in mind during review of punching shear include: 1. Large openings may affect the punching shear perimeter of nearby columns. We recommend … See more Answer: Punching-shear force (Vu) should be smaller than the column reaction, and similar to the value of column reaction minus column weight … See more 1- Verification examples of punching-shear calculations per various building codes are available within SAFE through Help > Documentation. 2- MacGregor's "Reinforced Concrete Mechanics and Design-Fourth … See more shark ion x40 filterWebMar 26, 2024 · For the purpose of this article, we will base our design basis on a Strip Based.From the Slab Design form, there are three types of reinforcing display available: Show Rebar Intensity, Show Total Rebar … popular human trafficking speakersWebOct 22, 2015 · I am importing first floor slab from Etabs 9.2 to safe 8.0. the problem i am facing is that safe is showing punching shear ratio values of the shear wall on which the slab is resting. Usually when we design foundation safe take wall reactions as a beam with intermediate points and shows N/C as punching shear ratio. popular housing in brazilWebApr 6, 2024 · Windows; Minimum Recommended; Operating system (OS) 98: Processor (CPU) Intel Pentium II 300 MHz AMD K6-III 450 MHz: System memory (RAM) 128 MB: … shark ipad caseWebOct 23, 2024 · Created by Mike Abell, last modified by Ondrej on Oct 23, 2024 The formulation for punching shear is presented in Context Help, which is available within the SAFE interface through Help > Documentation > Verification > ACI318. This verification example provides step-by-step calculations which serve as an overview of the punching … popular housewarming gifts for new homeowners